Lightning strike counter PLW-03AT

The PLW-03AT lightning strike counter is used to record lightning discharges into the lightning protection system of the protected building, and also allows checking of the technical condition of the GROMOSTAR T lightning rod without having to disassemble it.

The PLW-03AT recorder provides information: date, time of discharge and estimated value of the lightning current amplitude. It has the function of a GROMOSTAR T lightning rod tester (with built-in testable system). The lightning rod test is carried out at the user's request by activating the appropriate function. The PLW-03AT recorder has tele-transmission outputs.

Compliance with standards EN IEC 62561-6:2018-04
Minimum registered current Id 0,7 kA
Maximum registered current Imax 100 kA
Level of protection IP 54 
Operating temperature range od  -40ºC  do  +80ºC 
Dimensions 80 x 160 x 80 [mm] 
Weight 495 g 
External finishing ABS plastic in gray
Guarantee period 2 years
Max. average supply voltage 3,6 VC
Estimated battery life 3 years (no discharge)
 Battery test YES 
Lightning rod test  YES
Tele-transmission output  YES 
NC outputs information about discharge activation time 1 s.
NC outputs information about the lightning conductor test activation time 1 s.
Power consumption (normal state)  <0,4 µA
 Power consumption (displaying information)  <150mA
Storing of discharges 99 
Storing of discharges with date (above 1kA amplitude) 30 
Storing of discharges with date (amplitude from 0.2 kA - 1 kA) 10 

 

 

To download

Technical card in Polish - Counter PLW-03AT