GROMOSTAR lightning protection system

The GROMOSTAR system is a highly effective and modern solution in the field of lightning protection for people and property. It is characterized by the fact that a lightning strike is drawn by a PDA GROMOSTAR lightning conductor with an early emission of the leader. This device contains an induction-capacitive module initiating the development of a bottom-up leader in conditions where the top-down leader, rapidly developing from the cloud, is in the final stage of choosing a place before hitting the building – a solution based on a Polish patent registered in many countries of the world. It works by producing ionization earlier than other elements of the protected building, which results in directing the lightning current directly at the lightning rod and then with the discharge wire towards ground.

GROMOSTAR lightning rods are used to protect all kinds of structures, buildings and open areas against direct lightning.

Tests and certificates

According to the Expert opinion of the Expertise Centre of the Association of Polish Electrical Engineers SEP, GROMOSTAR lightning rods are a new solution for lightning protection of constructed buildings and external spaces, characterized by greater efficiency than traditionally used solutions. GROMOSTAR lightning protection systems can be used in buildings where lightning protection is required. Lightning rods increase the effectiveness of protection by creating a higher probability of the location of the discharge. This discharge due to the creation of pre-ionization conditions occurs faster than in the conditions of the traditional vertical lightning rod.

GROMOSTAR lightning rods have been tested in terms of efficiency, environment and high-current in high-voltage laboratories: SIAME at Pau University in France, at the Institute of Plasma Physics and Laser Microsynthesis in Warsaw and at the ITB Building Materials Laboratory in Warsaw, which confirmed the compliance of these products with NF C 17-102 (2011-09) standards and PN-EN 50164-1: 2010. In addition, additional tests carried out at the University of Pau's High Voltage Laboratory SIAME confirmed the greater effectiveness of GROMOSTAR lightning rods compared to the classic Franklin lightning rod* (*Test reports are available on request.)

 

The INSTITUTE OF ENERGY Research Institute in Warsaw confirmed the positive results of laboratory tests and the use of GROMOSTAR lightning protection systems in lightning protection systems, as well as the product's compliance with the requirements of NF C 17-102: 2011 and PN-EN 62561-1: 2012 by granting an IEn CERTIFICATE 002/2016 of 18-05-2016).

The lightning protection production process at ORW-ELS is subject to the requirements of the ISO 9001: 2008 quality management system and the rules of the Qualifoudre INERIS French Institute of Industry and Risk.

GROMOSTAR lightning conductors are protected by patents in Poland and abroad.

  • Greater efficiency - all structures in the protection zone, including antennas and roof decorations, are protected. In the case of conventional installations, the elements "protruding" above the terminals are exposed to lightning, which causes a direct threat to the building. The protection zone designated by the GROMOSTAR lightning rod is several times larger than when using a traditional high lightning rod.
  • The GROMOSTAR system allows the selective location of lightning strikes in such a way that its effects do not cause electrocutions of people gathered in the open or semi-open area (sports, recreational facilities, large groups of people, stadiums).
  • The short path of lightning current flow between the lightning conductor and the earth minimizes the risk of fire that may arise during a lightning discharge into a horizontal lightning rod along the roof contours (especially wooden or susceptible to fire).
  • The use of GROMOSTAR lightning rods significantly reduces the number of possible electromagnetic couplings between lightning current leads and electrical wiring, and thus reduces induced over-voltages in high and low current circuits.
  • Due to the smaller number of cables required to discharge lightning current to the ground, it is possible to keep a safe distance from cables and devices sensitive to electromagnetic interference.
  • High aesthetics and small interference in the roofing.
  • Proven, solid lightning rod design that can withstand multiple lightning strikes (covered by a 10-year warranty).
  • Reduction of investment and operating costs.

In individual construction, usually one properly installed lightning conductor on a lightning mast is sufficient. When installed on a free-standing mast, the protection area can include several buildings. Savings resulting from the use of GROMOSTAR installations can reach 50% of the costs of conventional installations.

The results of an analysis of the lightning protection installation costs for an industrial facility with dimensions of 250x250m made in I and IV protection level: the installation of GROMOSTAR lightning rods allows the saving of 47% of the costs compared to a traditional installation at the IV level. However, at level I, the cost difference reaches up to 72% in favour of the GROMOSTAR lightning protection technology. It can be assumed that the larger the building to be protected at the higher level of lightning protection, the higher the savings in with PDA technology.

It is also worth mentioning the costs associated with the subsequent operation of the installation. Due to the obligation for snow removal from the roof during winter, in the case of traditional installations equipped with horizontal joints, they often suffer severe damage, including tearing off. The use of GROMOSTAR lightning rods eliminates this problem.

  • GROMOSTAR lightning protection can also increase the efficiency of an existing lightning protection system. On buildings protected by horizontal low or high lightning rods, the installation of an additional GROMOSTAR lightning rod will direct the lightning discharge towards it, and the current will flow with the shortest leads to which it is connected.
  • A world-renowned technical solution. GROMOSTAR lightning conductors have been installed on thousands of facilities around the world. A dozen or so years of lightning discharge statistics conducted on facilities equipped with discharge recorders has confirmed the high efficiency and reliability of the GROMOSTAR system.

An example of a lightning protection installation made using the PDA - GROMOSTAR method